SPRIworks Fragment Library System I

Fully Automated Fragment Library System
for the Illumina* Genome Analyzer

The emergence of next generation sequencing technologies has enabled scientists to generate vastly increased data sets from their sequencing experiments. The increase in throughput, however, is supported by workflows that are relatively complicated and labor intensive, requiring skilled labor and significant hands-on time to prepare samples for each instrument. Beckman Coulter has created a simplified automated workflow that utilizes Solid Phase Reversible Immobilization (SPRI) paramagnetic bead based technology to create an automated system for fragment library preparation for the Illumina Genome Analyzer.

SPRIworks

SPRIworks Fragment Library System I throughput vs. manual library construction process for Illumina Genome Analyzer (one day process).

System Components

The SPRIworks Fragment Library System I includes:

  • The SPRI-TE Nucleic Acid Extractor
  • A method card that controls liquid handling
  • A cartridge containing all of the reagents required to prepare a single library

fragment library system

Product Features

  • Easy to use bench-top liquid handling system
  • Reagents pre-dispensed in a disposable cartridge
  • Automated purification of fragmented or sheared DNA
  • Optimized size selection chemistry – no more gels or columns
  • Process up to 10 samples in parallel per system in 5 hours
  • Reproducible and consistent library output
  • Libraries compatible with:
    • PCR-free workflow
    • Regular fragment or paired end adaptors
  • Reduced sequencing cost/sample
  • Improved sequencing service turnaround time

Library Creation in Four Simple Steps

cartridge
Step 1

Load SPRIworks Fragment Library Kit I Cartridge into the Rack

Load the reagent cartridge into the rack by grasping the labeled lip and sliding the reagent cartridge into the grooved channel. Slide the reagent cartridge all the way to the back of the channel, until it is retained at front and back.

amplicons
Step 2

Transfer Input Sample: Sheared DNA, cDNA or Amplicons

When all reagent cartridges are in position, load the Reagent Rack by grasping the handles and placing it into the extraction chamber. Place the input sample tube (fragmented DNA, or cDNA, or amplicons) in the empty position.

labware
Step 3

Load SPRI-TE with Cartridges, Input Samples, Adaptors and Labware

For each library to be constructed, insert one Piercing Tip and Sheath, two 1 mL Pipette Tips and Sheaths, one uncapped 2 mL Screw Cap Tube with Adapters, and one uncapped 2 mL Screw Cap Tube for the final library. If fewer than ten libraries are to be constructed during a run, align tips and tubes with the lane positions of the reagent cartridges in the Reagent Rack.
NOTE: Only use tips and tubes provided by Beckman Coulter.

For Each Library to be Constructed:

Insert a Piercing Tip and Sheath into row 1.

Insert a 1 mL Pipette Tip and Sheath into row 2.

Insert a 1 mL Pipette Tip and Sheath into row 3.

Aliquot 10 μL of adapters (50 μM) into a labeled, uncapped 2 mL Screw Cap Tube, and insert the tube into row 4.

Insert a labeled, uncapped 2 mL Screw Cap Tube into row 5. This tube will contain the fragment libraries at the conclusion of the run.

method card
Step 4

Insert Method Card and Press START

After loading the Reagent Rack and the Tip/Tube Racks onto the instrument and inserting the samples, start the run.

Close the instrument door and select the green START key.

The method appears in the LCD screen as SPRIworks Fragment Library System I. Specify your size selection or no size selection and press start.

After 5 hours the method is finished and you hear the instrument beep three times.

SPRIworks Sales and Support

To place an order in the United States and Canada call +1 800 526 3821.
For technical support in the United States and Canada call +1 800 854 3633 (Option #, 1, 3, 3).

Complete System
Product #
SPRIworks Fragment Library System I (For Illumina Genome Analyzer)
A88267
Includes:

SPRI-TE Instrument

SPRIworks Accessories Kit:

• Utility Card
• SPRI-TE Operator Manual CD
• SPRI-TE Step Feeler Gauge
• 1 mL Tips and Sheaths
• 200 μL Tips and Sheaths
• Elution Tubes
• Empty Reagent Cartridges
• SPRI-TE Operator Manual
• Piercing Tips and Sheaths

SPRIworks Fragment Library Kit I -10
(For Illumina Genome Analyzer):
• 10 cartridges for the preparation of 10 libraries
• SPRIworks Nebulization Buffer
• 1 mL Piercing Tips and Sheaths
• 200 μL Piercing Tips and Sheaths
• Elution Tubes
• Empty Reagent Cartridges


SPRIworks Method Card Kit for Fragment Library System I
(For Illumina Genome Analyzer)

Instructions for Use
SPRIworks Adapter I (For Illumina Genome Analyzer)
• Adaptor Tube - 10 Adaptors
• Forward Primer Mix Tube
• Reverse Primer Mix Tube
A84879
SPRIworks Nebulizer Kit 10
• 10 SPRIworks nebulizers each suitable for a single nebulization
A84871
SPRIworks Nebulizer Kit 50
• 50 SPRIworks nebulizers each suitable for a single nebulization
A84872
SPRIworks Fragment Library Kit I (For Illumina Genome Analyzer) 10
• 10 cartridges for the preparation of 10 libraries
• Piercing Tips and Sheaths
• 1 mL Tips and Sheaths
• Elution Tubes
• SPRIworks Nebulization Buffer
A84801
SPRIworks Fragment Library Kit I (For Illumina Genome Analyzer) 50
• 50 cartridges for the preparation of 50 libraries
• Piercing Tips and Sheaths
• 1 mL Tips and Sheaths
• Elution Tubes
• SPRIworks Nebulization Buffer
A84803